Mode Select
In this section, you must set the Receiver to CO (Central Oce), or CPE (Customer
Premises Equipment) operating modes. Select the Receiver mode, and once selected,
click the “Submit button to save the changes.
When using the 410VDSLEXT2, one end (Transmitter or Receiver) must always be set to
“CO mode, while the opposite end must always be set to “CPE” mode.
Setting each unit to CO or CPE mode is usually based on which direction you want
the most bandwidth delivered. “Download” bandwidth, data sent from CO to CPE, is
generally higher than “Upload” bandwidth from CPE to CO.
If you need higher bandwidth from the Transmitter Unit to the Receiver Unit, set the
mode to CPE.
If you need higher bandwidth from the Receiver Unit to the Transmitter Unit, set the
mode to CO.
Note: This setting will restart the 410VDSLEXT2
See the “DIP Switch Settings” section above to set the Transmitter Unit to the
appropriate CO or CPE mode based on the mode set for the Receiver Unit.